Laser Ablation

PCIGR’s versatile laser ablation systems can provide users with in-situ analyses via laser ablation ICP-MS for trace element analysis, isotopic analysis, and geochronology.

Make/modelConnection to
Resonetics RESOlution M-50-LR
(193 nm)
Agilent 7700x quadrupole ICP-MS and
Nu Instruments AttoM high-resolution ICP-MS
Elemental Science Lasers/New Wave Research NWR193UC (193 nm)Agilent 8900 triple-quadrupole ICP-MS

Resonetics RESOlution M-50-LR

The Resonetics RESOlution M-50-LR is a Class I laser system that features the  following:

  • Coherent COMPex Pro 110 UV excimer laser source (wavelength of 193 nm)
  • Laser spot size ranging from 5 to 200 µm
  • Sample stage (z-stage) for accurate beam focus, including on uneven surfaces
  • Two-volume sample cell (Laurin Technic, Australia) for high sensitivity, low fractionation, short washout times, and fast sample throughput
  • Large sample cell (Applied Spectra S-155) for large and/or irregularly shaped samples

This laser system allows for the ablation of a wide range of materials at high resolution and low absorbance. Our sample cells are capable of holding multiple samples of various dimensions, including:

  • Microscope slides
  • Mineral mounts
  • Thin rock sections
  • Slices of speleothem
  • Drill cores
  • Delicate archaeological materials (e.g., stone tools, teeth)
  • Samples of irregular shape
Photo of Resonetics RESOlution M-50-LR laser ablation system at PCIGR

Resonetics RESOlution M-50-LR laser ablation system being serviced at PCIGR. Photo: D. Weis. 

The RESOlution M-50-LR can be connected to PCIGR’s Agilent 7700x quadrupole ICP-MS and Nu Instruments AttoM high-resolution ICP-MS for split-stream, simultaneous trace elemental analysis and isotopic analysis.  

Contact pcigr@eoas.ubc.ca for details on instrumentation and submitting samples.
Consult the Fees page for analytical costs.

Back to top

 

NWR193UC

Photo of New Wave Research NWR193UC laser ablation system at PCIGR

New Wave Research NWR193UC laser ablation system at PCIGR. Photo: V. Lai.

The Elemental Scientific Lasers/New Wave Research NWR193UC laser ablation system features the following:

  • Coherent ExciStar XS ArF excimer laser source (wavelength of 193 nm)
  • Laser spot size ranging from 2 to 150 µm
  • TwoVol2 ablation cell fitted with a small cyclonic cup for efficient aerosol transport and washout

This laser system allows for the ablation of rock and mineral samples of various sizes and shapes.

Contact pcigr@eoas.ubc.ca for details on instrumentation and submitting samples.
Consult the Fees page for analytical costs.

back to top

First Nations land acknowledegement

We acknowledge that the UBC Point Grey campus is situated on the traditional, ancestral, and unceded territory of the xʷməθkʷəy̓əm.


UBC Crest The official logo of the University of British Columbia. Urgent Message An exclamation mark in a speech bubble. Caret An arrowhead indicating direction. Arrow An arrow indicating direction. Arrow in Circle An arrow indicating direction. Arrow in Circle An arrow indicating direction. Bluesky The logo for the Bluesky social media service. Chats Two speech clouds. Facebook The logo for the Facebook social media service. Information The letter 'i' in a circle. Instagram The logo for the Instagram social media service. External Link An arrow entering a square. Linkedin The logo for the LinkedIn social media service. Location Pin A map location pin. Mail An envelope. Menu Three horizontal lines indicating a menu. Minus A minus sign. Telephone An antique telephone. Plus A plus symbol indicating more or the ability to add. Search A magnifying glass. Twitter The logo for the Twitter social media service. Youtube The logo for the YouTube video sharing service.